OO-S-2822
3.6.4.2 Saw blade compartment. A lockable, weatherproof compartment shall be
provided and designed for holding the saw blades, dado heads and tools
furnished with the unit. Each blade shall be individually removable without
disturbing the other blades. The blade storage section shall be constructed so
the blade teeth will not contact other blades. Nonmetallic materials shall be
used to prevent contact of saw teeth with metal parts of the storage cabinet.
3.6.4.3 Saw accessories. Unless otherwise specified (see 6.2.1), the saw
accessories listed in table II shall be furnished with each saw machine in the
quantities and sizes indicated. The size of arbor holes shall be 1-inch (25.4
mm). Spacer collars shall be cadmium plated, cold rolled steel.
TABLE II.
Saw accessories.
3.6.4.4 Sawdust shield. A sawdust shield shall be installed between the
generator set and the saw on the type I mobile saw assembly. The shield shall
extend between the undercarriage frame side rails and shall be equivalent in
height to the generator housing. The shield shall be of all metal construction.
A sawdust shield for the type II mobile saw is not required.
Cord receptacles, cord plugs, and
3.6.5 Connectors, plugs, and receptacles.
outlet receptacles shall be of the grounding type and shall be in accordance
with UL 498, W-C-596, NEMA WD 1 and NEMA WD 6, as applicable. The cord
receptacles and cord plugs shall employ cord grip construction and shall be
weatherproof. Receptacles for type I shall be of the grounding type, 2-pole,
3-wire, 125V, 15 amperes, general purpose duplex.
3.6.6 Flexible power cords. Unless otherwise specified (see 6.2.1), all
power cords shall be in accordance with UL 62.
3.7 Lubrication. Means for lubrication shall be in accordance with the
manufacturer's standard practice. The lubricating points shall be easily
visible and accessible. Hydraulic lubrication fittings shall be in accordance
with SAE J534. Where use of high pressure lubricating equipment, 1,000
pound force per square inch (psi) or higher, will damage grease seals or other
parts, a suitable warning shall be affixed to the equipment in a conspicuous
location. The unit shall be lubricated prior to delivery with lubricants
designated for use in the -20 (-28.9°C) to 120°F (48.9°C) range. The unit shall
be conspicuously tagged to identify the lubricants and their temperature range.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business